Burdinurtuaglobuluavalve is a forced-sealing valve, so when the valve is closed, pressure must be applied to the disc to force the sealing surface to not leak. When the medium enters the valve from below the disc, the resistance that the operating force needs to overcome is the friction force of the valve stem and packing and the thrust generated by the pressure of the medium. The force to close the valve is greater than the force to open the valve, so BurdinurtuaThe diameter of the valve stem of the globuluavalve should be large, otherwise the valve stem will bend up failure.
2. Parameters of BurdinurtuaGlobuluaValve
Balbula mota
Burdinurtuaglobuluavalve
DN
DN10~DN600
PN(MPaï¼ ‰
1,6~16Mpa
Diseinatzeko Tenperatura Tartea
-15â „ƒï½ž200â„ ƒ
Konexio mota:
Bridatua
Eragingailu mota
Eskuzko eragiketa, Pneumatikoa, Hidraulikoa edo elektrikoa
Aplikagarria den euskarria
Ura, olioa, gasa eta hainbat korrosio-euskarri
Ordezko piezak
Materiala
Gorputz-azaleko diskoa
Altzairu forjatua, Altzairu galdatua
Zurtoina
Altzairu forjatua, Altzairu galdatua
Ontziratzea
Grafito malgua, grafito malgu hobetua, PTEE
Shim zigilatzea
Flexiblo grafito hobetua, altzairu tindagarria, PTFE
Aurpegi zigilatzailea
13Cr,STL, PTFE, Nylon, Gorputz materialarekin
3. Advantages of Burdinurtuaglobuluavalve
1) The structure of the Burdinurtuaglobuluavalve is simpler than that of the gate valve, and it is more convenient to manufacture and maintain.
2) Zigilatzeko gainazalaof Burdinurtuaglobuluavalve is not easy to wear and scratch, and the sealing performance is good. There is no relative sliding between the valve disc and the sealing surface of the valve body when opening and closing, so neither abrasion nor abrasion is serious. The sealing performance is good and the service life is long. .
3) When the Burdinurtuaglobuluavalve is opened and closed, the disc stroke is small, so the height of the shut-off valve is smaller than that of the gate valve, but the structure length is longer than that of the gate valve.
4) Burdinurtuaglobuluavalve has a large opening and closing moment, which is laborious and takes a long time.
5) The medium channel in the Burdinurtuaglobuluavalve is tortuous, the fluid resistance is large, and the power consumption is large.
6) When the nominal pressure of the medium flow direction of the Burdinurtuaglobuluavalve PN≤16MPa, the downstream flow is generally adopted, and the medium flows upward from the bottom of the valve flap; when the nominal pressure PN≥20MPa, the reverse flow is generally adopted, and the medium flows downward from the top of the valve flap. In order to increase the seal performance. When in use, the shut-off valve medium can only flow in one direction and cannot change the direction of flow.
7) The valve flap is often eroded when the Burdinurtuaglobuluavalve is fully opened.
4. Ohiko galderak